Flex-Circuit Design Guide

Document source : www.alflex.nl


Terminations
There are a variety of terminations for a flex-circuit, and
a variety of methods for applying these terminations.
·
Connectors are usually customer selected, and can
be attached by hand-soldering, wave-soldering, or
crimping in the case of insulation displacement
connectors (IDC's). DuPont ClincherTM connectors
are a good option for many applications. Connectors
can be potted after attachment or conformally coated
for protection and insulation with epoxy, polyurethane,
or RTV.
·
Fingers can be supported or unsupported.
Clincher connector
Connector
Fingers
Connector Type
Centerline Distance
Clincher Connector
0.100" min.
Other types: pin
center-to-center
0.050" min.
Finger Type
Centerline Distance
Supported
0.006" min.
Unsupported
0.020" min.
Application Aid #24
Tel: (763) 571-3121 K Fax: (763) 571-0927 K www.minco.com
15







Summary :

· Connectors are usually customer selected, and can be attached by hand-soldering, wave-soldering, or crimping in the case of insulation displacement connectors (IDC's). Clincher connector Connector Fingers Connector Type Centerline Distance Clincher Connector 0.100"


Tags : connector,connectors,min,terminations,763,supported,clincher,insulation,fingers,centerline,distance,unsupported,type





Terms    |    Link pdf-search-files.com    |    Site Map
   |    Content Removal Notice   
   |    Contact   

All books are the property of their respective owners.
Please respect the publisher and the author for their creations if their books copyrighted