4-11
Enterprise Network Virtualization Access Control System Assurance Guide
Chapter 4 Network Virtualization - Managed Partner Access Deployment
4.1 Managed Partner Access Deployment Configuration
8.
Enable Auth-failed VLAN on the switch. This is an optional step, to provide limited access to the
Partner user when invalid credentials are provided.
a.
Enable Auth-Failed VLAN on the access port
Cat OS configuration:
Set port dot1x <mod/port> auth-fail-vlan <vlan#>
IOS configuration:
dot1x auth-fail vlan 275
9.
Enable MAB on the access switch. This is an optional step, only if MAB is enabled as fallback
solution. It includes following sub steps:
a.
Enable MAB global, this only requires on CATOS
set mac-auth-bypass enable
Summary :
4-11 Enterprise Network Virtualization Access Control System Assurance Guide Chapter 4 Network Virtualization - Managed Partner Access Deployment 4.1 Managed Partner Access Deployment Configuration 8.
Tags :