Home

This document is a cache from http://www.bb-elec.com/bb-elec/literature/manuals/anywhereusb.pdf


Anywhere USB®

Document source : www.bb-elec.com

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 All Pages

AnywhereUSB Installation Guide (90000405 Rev. F) ­ Page 12
European Community - CE Mark
Declaration of Conformity (DOC)
According to ISO/IEC Guide 22 and EN 45014
Manufacturer's Name:
Digi International
Manufacturer's Address:
11001 Bren Road East
Minnetonka, MN 55343
declares that the product
Product Name:
AnywhereUSB
Model Number(s):
301-1130-01
Product Options:
All
conforms to the relevant EU Directives listed
here:
EMC Directive 89/336/EEC |
Low Voltage Directive 73/23/EEC
Amending Directive 93/68 EEC
using the relevant section of the following EU
standards and other normative documents:
Safety:
IEC 950:1991 +A1, A2, A3, A4
EN 60950:1992 + A1, A2, A3, A4
EMC
The following summarizes the specifications and
requirements for EN55024, EN55022 Class B &
CISPR 22 Class B emission and immunity tests.
If the actual test levels are higher or different
than required, these levels are listed in the
appropriate tables.
EN 55022 Class B
(1994 w/A1 1995)
Test
Specification
EN55024
Requirement
Electrostatic
Discharge
EN61000-4-2
+4 kV contact
+8kV air
Radiated Immunity EN61000-4-3
3 V/m
Electrical Fast
Transient Burst
EN61000-4-4
1kV (A/C), .5kV (I/O)
Surge
EN61000-4-5
2kV common mode
1kV differential mode
Conducted
Immunity
EN61000-4-6
3V rms
Magnetic Immunity EN61000-4-8
1 A/m Not Applicable
Voltage Dips &
Interrupts
EN61000-4-11
>95%, 30% & >95%
EN55024 (1998)
Test
Specification
EN55022
Requirement
Radiated Emissions --
Class B
Conducted
Emissions
CISPR 22
Class B
European Contact
Digi International
Joseph-von-Fraunhofer Str. 23
44227 Dortmund, GERMANY
49-231-9747-0
UL/CSA Safety Information
This device complies with the requirements of
following safety standards below:
UL 1950, 3rd edition
CSA No. 950
Quality Manager
Austin, Texas
July 2006

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 All Pages






Summary :

EN 55022 Class B (1994 w/A1 1995) Test Specification EN55024 Requirement Electrostatic Discharge EN61000-4-2 +4 kV contact +8kV air Radiated Immunity EN61000-4-3 3 V/m Electrical Fast Transient Burst EN61000-4-4 1kV (A/C), .5kV (I/O) Surge EN61000-4-5 2kV common mode 1kV differential mode Conducted Immunity EN61000-4-6 3V rms Magnetic Immunity EN61000-4-8 1 A/m Not Applicable Voltage Dips &