Home

This document is a cache from http://www.avg.net/Downloads/PG98R001.PDF


Press Guide 98****

Document source : www.avg.net


· PLS Module for press automation - 16 channels
· DIE PROTECTION Module - 8 inputs
· SHUT HEIGHT CONTROL Module - Resolver based
· SHUT HEIGHT CONTROL Module - Linear Rod based
· LOAD MONITOR Module - Signature or Tonnage at angle Module- 4 sensor inputs
· LOAD MONITOR Module - Peak Tonnage-4 sensor inputs
· COMMUNICATION Module - Tonnage Display
M1950-P10 Plug-in Modules...
-INTEGR
A
TED C
ONTROL SY
STEMS-
A
U
T
OMA
TION C
ONTROL & MONIT
ORING SY
STEMS
Variety of Modules
AVG-Autotech currently offers several modules for press control functions:
Each of these modules offers advanced features. These features are described below:
M1950-P10
35
Application HOT-LINE 1-800-TEC-ENGR · www.avg.net
PLS Module
Programmable Limit Switch (PLS) provides timing signals
for press automation functions such as Lube, Part Eject,
Feed Advance, etc. The M1950 PLS module offers 16
channels with advanced features, which are plenty for
most press applications. For applications requiring more
outputs, more than one module may be used. The module
has the following features:
·
16 logic level optically isolated outputs
·
Storage for up to 100 setups for quick
job changeover
·
Multiple dwells for each channel
·
Each channel can be used as Angle ON -
Angle OFF, or as Angle ON - Time OFF.
An Angle On - Time Off channel turns ON
outputs at an angle for preset time.
·
Fine tune in motion allows you to modify
dwells without shutting down press
·
Outputs "N" type Sinking or "P" type Sourcing
·
Scale Factor: Programmable from 16 to 999
(Resolution 17 to 1000 counts; typ. press
application - 360 counts)
Die Protection Module
The die protection module helps protect expensive dies
by ensuring proper material progression throughout the
press stroke. Appropriately located sensors (proximity,
photo eye, etc.) monitor material progression. The module
checks sensors constantly for programmed events during
programmed dwells. The M1950 die protection module
can monitor up to 8 sensor inputs. The module has the
following features:
·
8 optically isolated sensor inputs
·
Programmable sensor events, such as Sensor
Low, High, Rising edge, falling edge, pulse
·
Programmable multiple dwells for
monitoring sensors
·
Programmable sensor names allow you to
refer sensor by their functions, such as
Feed, Eject, etc.
·
Each sensor fault can be independently
associated with either E-Stop output
or with T-Stop output
·
2 Counters for Batch and Part Quality







Summary :

· PLS Module for press automation - 16 channels · DIE PROTECTION Module - 8 inputs · SHUT HEIGHT CONTROL Module - Resolver based · SHUT HEIGHT CONTROL Module - Linear Rod based · LOAD MONITOR Module - Signature or Tonnage at angle Module- 4 sensor inputs · LOAD MONITOR Module - Peak Tonnage-4 sensor inputs · COMMUNICATION Module - Tonnage Display M1950-P10 Plug-in Modules...


Tags : sensor,press,angle,features,programmable,inputs,each,modules,dwells,outputs,die,pls,monitor